首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于硫堇/碳纳米管修饰电极的新型过氧化氢电化学传感器
引用本文:邓春艳,阳明辉.基于硫堇/碳纳米管修饰电极的新型过氧化氢电化学传感器[J].分析测试学报,2012,31(7):828-832.
作者姓名:邓春艳  阳明辉
作者单位:1. 中南大学化学化工学院,有色金属资源化学教育部重点实验室,湖南长沙410083;湖南大学化学化工学院,化学生物传感与计量学国家重点实验室,湖南长沙410082
2. 中南大学化学化工学院,有色金属资源化学教育部重点实验室,湖南长沙410083
基金项目:国家自然科学基金(21005090);湖南大学化学生物传感与计量学国家重点实验室开放基金
摘    要:基于碳纳米管(CNTs)和硫堇(Th)的协同效应,将辣根过氧化物酶(HRP)通过戊二醛(GA)交联作用固定在硫堇(Th)/CNTs修饰电极上,构造了一种新型酶电极(HRP/GA-Th/CNTs/GC)。CNTs静电吸附正电荷的Th,而Th不仅可以促进电极和酶的氧化还原活性中心之间的电子传递,而且能使CNTs氨基(—NH2)功能化,从而利于HRP的固定。基于HRP/GA-Th/CNTs/GC电极的过氧化氢传感器具有较好的传感性能,且检出限低(0.3μmol.L-1)、响应时间短(5 s内)、抗干扰能力强。

关 键 词:碳纳米管  辣根过氧化物酶  硫堇  协同效应  过氧化氢  电化学传感器

A Novel Amperometric Hydrogen Peroxide Biosensor Based on Thionine-Carbon Nanotube Modified Glassy Carbon Electrode
DENG Chun-yan , YANG Ming-hui.A Novel Amperometric Hydrogen Peroxide Biosensor Based on Thionine-Carbon Nanotube Modified Glassy Carbon Electrode[J].Journal of Instrumental Analysis,2012,31(7):828-832.
Authors:DENG Chun-yan  YANG Ming-hui
Institution:1(1.Key Laboratory of Resources Chemistry of Nonferrous Metals,College of Chemistry and Chemical Engineering,Central South University,Changsha 410083,China;2.State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering,Hunan University,Changsha 410082,China)
Abstract:Based on the synergic effect of multi-walled carbon nanotubes(CNTs) and thionine(Th),a novel hydrogen peroxide electrode(HRP/GA-Th/CNTs/GC) was fabricated by immobilizing horseradish peroxidase(HRP) onto the thionine(Th) /multi-walled carbon nanotubes modified electrode via glutaradehyde(GA) cross-linking.The introduction of CNTs into the electrode is helpful for the further immobilization of Th and the catalysis to H2O2.Furthermore,Th immobilized on CNTs by electrostatic adsorption not only can transfer electrons between the electrode and the redox activity center of the enzyme,but also can enable amine group(—NH2) in Th to provide convenience for the immobilization of HRP enzyme via glutaradehyde cross-linking.Additionally,effects of various experimental parameters on H2O2 sensing,including applied potential,pH value and electroactive interferent,were investigated.At an optimal potential of-0.3 V,the current response of the biosensor in phosphate buffer(pH 7.0) was linear with H2O2 concentration from 5 μmol·L-1 to 40 μmol·L-1,with a good detection limit(0.3 μmol·L-1),a short response time(within 5 s) and a good anti-interferent ability.
Keywords:multi-walled carbon nanotubes  horseradish peroxidase  thionine  synergistic effect  hydrogen peroxide  biosensor
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《分析测试学报》浏览原始摘要信息
点击此处可从《分析测试学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号