High-performance liquid chromatographic assay for amiodarone N-deethylation in microsomes of rat liver.
Authors:J M Trivier  J Pommery  C Libersa  J Caron  M Lhermitte
Institution:Département de Biochimie, H?pital Calmette, Lille, France.
Abstract:A reversed-phase high-performance liquid chromatographic assay using ultraviolet detection is described for determining the production of the major N-dealkylated metabolite of amiodarone in rat liver microsomes. The principal advantages of this method are its simple sample preparation (protein precipitation by acetonitrile), low detection limit for N-desethylamiodarone (0.05 mumol/l) and relatively short analysis time (16 min). Its analytical applicability is demonstrated by the comparison of the kinetic parameters (maximum velocity and Michaelis-Menten constant) between Sprague-Dawley and Dark-Agouti rats.