首页 | 本学科首页   官方微博 | 高级检索  
     检索      


LC-MS determination of linear alkylbenzene sulfonates and their carboxylic degradation products in influent and effluent water samples and sludges from sewage-treatment plants
Authors:J Riu  E Marínez  D Barceló  A Ginebreda  L L Tirapu
Institution:Department of Environmental Chemistry, IIQAB-CSIC, Barcelona, Spain.
Abstract:Linear alkylbenzene sulfonates (LAS) have been determined in samples of the influent and the effluent, and in the sludge, from sewage-treatment plants (STP). LAS and sulfophenyl carboxylate compounds (SPC) were isolated by solid-phase extraction (SPE) with the polymeric phase Isolute ENV, then determined by liquid chromatography-electrospray mass spectrometry (LC-ESI-MS). The method enabled unequivocal identification of C10-C13 LAS by monitoring the ion at m/z 183 and the base peak corresponding to the M-H]- ion. Average recoveries varied from 77-93% and the linear range of the method varied from 0.2 to 10 microg L(-1), with a limit of detection ranging from 10 ng L(-1) to 1.5 microg L(-1) when 200 mL waste water were preconcentrated. For sewage sludge, recoveries varied from 58 to 90% and the linear range was between 0.2 and 100 microg L(-1), with a detection limit ranging from 0.4 to 120 microg kg(-1) when 2.5 g sewage sludge was extracted. Unequivocal identification and determination of some metabolites of the LAS, the sulfophenyl carboxylate compounds (SPC), was achieved by monitoring M-H]- ions.
Keywords:
本文献已被 SpringerLink 等数据库收录!