首页 | 本学科首页   官方微博 | 高级检索  
     检索      


An analysis of avidin, biotin and their interaction at attomole levels by voltammetric and chromatographic techniques
Authors:Rene Kizek  Michal Masarik  Karl J Kramer  David Potesil  Michele Bailey  John A Howard  Borivoj Klejdus  Radka Mikelova  Vojtech Adam  Libuse Trnkova  Frantisek Jelen
Institution:(1) Department of Chemistry and Biochemistry, Mendel University of Agriculture and Forestry, Zemedelska 1, 613 00 Brno, Czech Republic;(2) Laboratory of Biophysical Chemistry and Molecular Oncology, Institute of Biophysics, Academy of Sciences of the Czech Republic, Kralovopolska 135, 612 65 Brno, Czech Republic;(3) Grain Marketing and Production Research Center, Agricultural Research Service, US Department of Agriculture, Manhattan, KS 66502, USA;(4) Department of Analytical Chemistry, Faculty of Science, Kotlarska 2, 611 37 Brno, Czech Republic;(5) ProdiGene Inc, 101 Gateway Boulevard, College Station, TX 77845, USA;(6) Department of Theoretical and Physical Chemistry, Faculty of Science, Kottarska 2, 611 37 Brno, Czech Republic
Abstract:The electroanalytical determination of avidin in solution, in a carbon paste, and in a transgenic maize extract was performed in acidic medium at a carbon paste electrode (CPE). The oxidative voltammetric signal resulting from the presence of tyrosine and tryptophan in avidin was observed using square-wave voltammetry. The process could be used to determine avidin concentrations up to 3 fM (100 amol in 3 mgrl drop) in solution, 700 fM (174 fmol in 250 mgrl solution) in an avidin-modified electrode, and 174 nM in a maize seed extract. In the case of the avidin-modified CPE, several parameters were studied in order to optimize the measurements, such as electrode accumulation time, composition of the avidin-modified CPE, and the elution time of avidin. In addition, the avidin-modified electrode was used to detect biotin in solution (the detection limit was 7.6 pmol in a 6 mgrl drop) and to detect biotin in a pharmaceutical drug after various solvent extraction procedures. Comparable studies for the detection of biotin were developed using HPLC with diode array detection (HPLC-DAD) and flow injection analysis with electrochemical detection, which allowed biotin to be detected at levels as low as 614 pM and 6.6 nM, respectively. The effects of applied potential, acetonitrile content, and flow rate of the mobile phase on the FIA-ED signal were also studied.
Keywords:Avidin  Biotin  Avidin–  biotin technology  Square-wave voltammetry  Modified electrode  High-performance liquid chromatography  Diode array detection  Electrochemical transfer technique  Carbon paste electrode  Drug analysis
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号