首页 | 本学科首页   官方微博 | 高级检索  
     检索      


QUANTUM YIELDS FOR LASER PHOTOCYCLIZATION OF BILIRUBIN IN THE PRESENCE OF HUMAN SERUM ALBUMIN. DEPENDENCE OF QUANTUM YIELD ON EXCITATION WAVELENGTH
Authors:Antony F  McDonagh †  Giovanni  Agati  Franco  Fusi Riccardo  Pratesi †
Institution:Department of Medicine and the Liver Center, Box 0538, University of California, San Francisco, CA 94143, USA;CNR, Istituto di Elettronica Quantistica, Via Panciatichi, 56/30, 50127 Firenze, Italy
Abstract:The quantum yield for laser photocyclization of bilirubin to lumirubin in the presence of human serum albumin (phi LR) was measured at five monochromatic excitation wavelengths in the range 450-530 nm. Solutions used were optically thin throughout the wavelength range and precautions were taken to exclude contributions from photocyclization of bilirubin XIII alpha impurities. The values obtained (7.2-18 x 10(-4] were lower than those previously reported and showed the following wavelength dependence: 457.9 less than 488.0 less than 501.7 less than 514.5 approximately equal to 528.7. However, the rate of lumirubin formation, normalized to constant fluence, decreased with wavelength over the same wavelength range and no evidence was found that photoisomerization of bilirubin to lumirubin is faster with green (514.5 or 528.7 nm) than with blue (457.9 or 488.0 nm) light. The stereoselectivity of the configurational isomerization of bilirubin to 4Z,15E and 4E,15Z isomers also was studied. This reaction became less regioselective for the 4Z,15E isomer with increasing wavelength. The observed wavelength dependence of phi LR and of the 4E,15Z]: 4Z,15E] ratio at photoequilibrium are consistent with an exciton coupling model in which intramolecular energy transfer can occur between the two pyrromethenone chromophores of the bilirubin molecule in the excited state. Relative rates of lumirubin formation in vivo at different excitation wavelengths and constant fluence were estimated for different optical thicknesses and for different skin thicknesses. These estimates suggest that the recently reported clinical equivalence of blue and green phototherapy lights probably reflects the marked variation of skin transmittance with wavelength more than wavelength-dependent photochemistry. The calculations also indicated that the optimal wavelength for phototherapy is probably on the long wavelength side of the bilirubin absorption maximum.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号