AC susceptibility of magnetic markers in suspension for liquid phase immunoassay |
| |
Authors: | Keiji Enpuku Tsuyoshi Tanaka Yuya Tamai Masaaki Matsuo |
| |
Affiliation: | Research Institute of Superconductor Science and Systems, Kyushu University, Fukuoka 819-0395, Japan |
| |
Abstract: | AC susceptibility of magnetic markers in solution was studied for biosensor applications. First, frequency dependence of the susceptibility was measured, and size distribution of the markers was estimated by analyzing the experimental result with the so-called singular value decomposition (SVD) method. The size distribution estimated with the magnetic measurement agreed with that obtained from conventional optical measurement. Next, susceptibility measurement was applied to the liquid-phase immunoassay without bound/free (B/F) separation. We performed the detection of biotin-coated polymer beads in suspension using avidin-coated magnetic markers. Changes of the susceptibility and the size distribution caused by the binding reaction were shown. |
| |
Keywords: | Magnetic marker Size distribution AC susceptibility Brownian relaxation Singular value decomposition method Liquid phase immunoassay |