引用本文:冯素玲,唐安娜,樊静. 荧光分析法测定痕量亚硝酸根[J]. 分析试验室, 2001, 20(2): 41-43
作者姓名:冯素玲  唐安娜  樊静
作者单位:河南师范大学化学系
摘    要:在硫酸介质中,亚硝酸根能还原吡咯红Y,使其荧光猝灭据此提出了一个测定痕量亚硝酸根的荧光分析法,方法的检出限为2.7ng/mL,线性范围为6.0-88ng/mL,可直接用于电厂废水、自来水、井水中亚硝酸根的测定。

关 键 词:荧光分析法 亚硝酸根 吡咯红Y 痕量分析 电厂废水 井水 自来水
文章编号:1000-0720(2001)02-0041-03

Determination of Nitrite by Fluorimetric Method
FENG Su ling ,TANG An na and FAN Jing. Determination of Nitrite by Fluorimetric Method[J]. Chinese Journal of Analysis Laboratory, 2001, 20(2): 41-43
Authors:FENG Su ling   TANG An na    FAN Jing
Affiliation:FENG Su ling *,TANG An na and FAN Jing
Abstract:A simple and sensitive fluorimetric method was proposed fordetermination of nitrite. The method was based on the reduction of pyronine Y by NO-2 in the sulfuric acid medium. The detection limit for nitrite is 2.7 ng/mL, the linear range of the determination is 6.0~88 ng/mL. The method was used to determine nitrite in electroplanting waste water,tap water and well water samples.