Microdialysis sampling and high-performance liquid chromatography with chemiluminescence detection for in-vivo on-line determination and study of the pharmacokinetics of levodopa in blood
Authors:Chen?Funan  Email author" target="_blank">Zhang?ZhujunEmail author  Zhang?Yingxue  He?Deyong
Institution:(1) Institute of Analytical Science, Southwest Normal University, Chongqing, 400715, PR China;(2) Department of Chemistry, Qiongzhou University, Hainan, 572200, PR China
Abstract:A simple, reliable, and reproducible method for in-vivo on-line separation and determination of levodopa has been based on microdialysis then high-performance liquid chromatography with chemiluminescence detection. The perfusate is perfused at a flow rate of 5 mgrL min–1. The concentration of levodopa in the dialysate is determined on line with a chemiluminescence system. The dialysate sample volume is approximately 20 mgrL. The response of the system is linearly related to the concentration of levodopa in the range 1×10–8 to 1×10–6 g mL–1 (r2=0.9995) with a detection limit (3sgr) of 3×10–9 g mL–1 and sample throughput of 12 h–1; RSD is 2.8% (n=11). The method has been successfully used to study the pharmacokinetics of levodopa in vivo; the values of the pharmacokinetics parameters Cmax, AUC0–t and Tmax were 16.60, 20.92 ng mL–1, and 90 min, respectively.
Keywords:Levodopa  Quantitative microdialysis  In-vivo analysis  Chemiluminescence  HPLC  Pharmacokinetics