首页 | 本学科首页   官方微博 | 高级检索  
     

固相萃取-气相色谱-负化学源质谱法测定人血清中的多溴联苯醚
引用本文:Huang F,Zhao Y,Li J,Wu Y. 固相萃取-气相色谱-负化学源质谱法测定人血清中的多溴联苯醚[J]. 色谱, 2011, 29(8): 743-749. DOI: 10.3724/SP.J.1123.2011.00743
作者姓名:Huang F  Zhao Y  Li J  Wu Y
作者单位:中国疾病预防控制中心营养与食品安全所, 北京 100050
基金项目:国家“十一五”科技支撑计划项目(2007BAC27B02); 卫生公益性行业科研专项基金项目(200902009); 中国博士后科学基金项目(20090450459)
摘    要:采用OasisHLB固相萃取柱萃取血清中的多溴联苯醚(PBDEs),经浓硫酸柱上除脂后,利用气相色谱-负化学源质谱法测定BDE-17、28、47、66、99、100、153、154、183和209共10种PBDEs组分。BDE-209的测定采用DB-5 ms色谱柱(15 m×0.25 mm×0.1 μm),其他组分采用VF-5 ms色谱柱(30 m×0.25 mm×0.25 μm)。对样品中蛋白质的去除溶剂和固相萃取条件(如洗脱溶剂及其用量)进行了优化。胎牛血清中的加标回收试验结果显示,各PBDEs单体相对于内标的平均回收率为78.5%~109.7%,日内测定的相对标准偏差(RSD)为0.3%~7.4%,日间测定的RSD为1.4%~14.1%。胎牛血清中三溴~七溴联苯醚的检出限(信噪比为3)为0.10~0.27 ng/L;定量限(信噪比为10)除了BDE-209为7.91 ng/L外,其他PBDEs为0.35~0.91 ng/L。采用本方法测定标准参考物质SRM1957和SRM1958,结果在参考值范围内。实验结果表明,本方法灵敏度高、准确度和精密度好,简便快速,溶剂消耗量少,适用于人体血清中三至十位溴取代联苯醚的测定。

关 键 词:固相萃取  气相色谱-负化学源质谱  多溴联苯醚  血清
收稿时间:2011-04-03

Determination of polybrominated diphenyl ethers in human serum using solid-phase extraction and gas chromatography coupled with negative chemical ionization mass spectrometry
Huang Feifei,Zhao Yunfeng,Li Jingguang,Wu Yongning. Determination of polybrominated diphenyl ethers in human serum using solid-phase extraction and gas chromatography coupled with negative chemical ionization mass spectrometry[J]. Chinese journal of chromatography, 2011, 29(8): 743-749. DOI: 10.3724/SP.J.1123.2011.00743
Authors:Huang Feifei  Zhao Yunfeng  Li Jingguang  Wu Yongning
Affiliation:National Institute of Nutrition and Food Safety, Chinese Center for Disease Control and Prevention, Beijing 100050, China
Abstract:A simplified analytical method comprised of solid-phase extraction (SPE) and gas chromatography coupled with negative chemical ionization mass spectrometry (GC-NCI/MS) has been developed for the determination of 10 polybrominated diphenyl ethers (PBDEs) congeners in human serum. After the extraction by Oasis HLB custom-made SPE cartridges, the lipids in serum were decomposed by concentrated sulfuric acid directly added on the SPE column. The solvent for protein cleanup and the SPE conditions, such as elution solvent and its volume were optimized. The recoveries of the PBDEs spiked in fetal bovine serum relative to internal standards were in the range of 78.5% - 109.7% at five spiked levels (three spiked levels for BDE-209). The intra-day relative standard deviations (RSDs) were between 0.3% and 7.4%, while the inter-day RSDs were between 1.42% and 14.1%. The limits of detection (LOD, S/N = 3) and the limits of quantification (LOQ, S/N = 10) were in the range of 0.10 - 0.27 ng/L and 0.35 -0.91 ng/L respectively for all PBDEs, except BDE-209. The LOQ (blank concentration value x 3) for BDE-209 was 7.91 ng/L. The method was verified by accurate analysis of organic contaminant standard reference materials (SRM) 1957 and 1958. The results indicated that the proposed method is sensitive, accurate, fast, simple, low solvent consumption and suitable for the determination of tri- to deca-BDE in human serum.
Keywords:solid-phase extraction(SPE)  gas chromatography coupled with negative chemical ionization mass spectrometry(GC-NCI/MS)  polybrominated diphenyl ethers(PBDEs)  serum  
本文献已被 CNKI PubMed 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号