首页 | 本学科首页   官方微博 | 高级检索  
     

Fe-CAS-NH4F-OP体系高灵敏度分光光度法测定二氧化硅中微量铁
引用本文:冯先进. Fe-CAS-NH4F-OP体系高灵敏度分光光度法测定二氧化硅中微量铁[J]. 光谱实验室, 1999, 16(3): 287-289
作者姓名:冯先进
作者单位:北京矿冶研究总院分析室,北京市西直门外文兴街1号,100044
摘    要:在HAc-NH4Ac缓冲介质中,当有NH4F和乳化剂OP存在时,Fe与CAS形成络合比为1:3的有色络合物,其最大吸收波长位于654.0nm,表观摩尔吸光系数为1.18×10^5L·mol^-1·cm^-1,1-20μg Fe/50mL线性关系良好。该法用于二氧化硅中铁的测定,结果令人满意。

关 键 词:分光光度法    铬天青S  聚乙二醇辛基苯基醚  二氧化硅

Spectrophotometric Determination of Iron in silica oxide with Fe-CAS-NH4F-OP High Sensitive System
FENG Xian-Jin. Spectrophotometric Determination of Iron in silica oxide with Fe-CAS-NH4F-OP High Sensitive System[J]. Chinese Journal of Spectroscopy Laboratory, 1999, 16(3): 287-289
Authors:FENG Xian-Jin
Abstract:The presence of NH4F and surfactant p|octye polyethylene glycol phenyl (OP),iron forms sensitive colored complex with chrome azurol S(CAS).Composition ratio of the complex is 13.The maximum absorption wavelength is 654nm and its apparent molar absorptivity is 1.18105Lmol-1cm-1,following beer's law at range Fe 1-20g/50mL.The method has been applied to determination of iron in silica oxide with satisfactory results.
Keywords:Spectrophotometry  Iron  CAS  OP  Silica Oxide.