首页 | 本学科首页   官方微博 | 高级检索  
     

连续波氧碘激光对光伏型锑化铟探测器的破坏阈值
引用本文:陈金宝 陆启生. 连续波氧碘激光对光伏型锑化铟探测器的破坏阈值[J]. 强激光与粒子束, 1998, 10(2): 221-224
作者姓名:陈金宝 陆启生
作者单位:国防科技大学应用物理系,长沙 410073
基金项目:国家863激光技术领域资助
摘    要: 通过测量光伏型锑化铟探测器在不同功率密度的连续波氧碘激光辐照下性能的变化,得到其破坏阈值范围为26(089s)~113(14s)W/cm2。 理论上用一维热模型计算了探测器在激光辐照过程中温升和输出信号的变化过程,对实验结果进行了分析。

关 键 词:光电探测器  连续波氧碘激光  破坏阈值
收稿时间:1900-01-01;

DAMAGE THRESHOLD OF CW COIL TO InSb(PV) DETECTOR
Chen Jinbao,Lu Qisheng,Zhong Hairong,Jiang Zhiping,Liu Zejin. DAMAGE THRESHOLD OF CW COIL TO InSb(PV) DETECTOR[J]. High Power Laser and Particle Beams, 1998, 10(2): 221-224
Authors:Chen Jinbao  Lu Qisheng  Zhong Hairong  Jiang Zhiping  Liu Zejin
Affiliation:Chen Jinbao,Lu Qisheng,Zhong Hairong,Jiang Zhiping,Liu Zejin Department of Applied Physics,National University of Defence Technology,Changsha,410073
Abstract:The performance change of PV InSbdetector illuminated by CW COIL with different power density was measured.The damage threshold range of the detector wasachieved to be 26(089s)~113(14s)W/cm2.Thetemperautre rise and output signal of PV InSb detector illuminated by CW laser werecalculated with one dimensional thermal model and the experimental result was analyzed.
Keywords:photoelectric detector  CW COIL  damage threshold
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《强激光与粒子束》浏览原始摘要信息