柴油发电机组自启动问题解决一例 |
| |
引用本文: | 刘洪峰. 柴油发电机组自启动问题解决一例[J]. 通信电源技术, 2000, 0(3): 43-44 |
| |
作者姓名: | 刘洪峰 |
| |
摘 要: | 通过对帕金期自动柴油发电机在市电缺相故障时不能自启动供电的问题分析,提出了对ATS控制屏电路进行改造的方案。实践证明,该方案投资少、见效快、可靠性高。
|
关 键 词: | 柴油发电机组 自启动 ATS控制屏 |
An Example on Auto-start Solution to Diesel Generating-set |
| |
Abstract: | The article analyses the problem that Parkins auto Diesel is not able to auto-start to supply power at Mains failure, and puts forward the reform solution to ATS control panel circuit.It is proved by practices that the solution is of low investment, fast efficient and high reliability. |
| |
Keywords: | diesel generating-set auto-start ATS control panel |
本文献已被 维普 等数据库收录! |