Chromatographic determination of tetramethrin on woolen cloth and in aqueous treatment formulations |
| |
Authors: | R A Simonaitis R S Cail |
| |
Institution: | (1) Stored-Product Insects Research and Development Laboratory, Agricultural Research Service, USDA, 31403 Savannah, GA, USA |
| |
Abstract: | Summary A method is described for the analysis of tetramethrin aqueous formulation and residues of tetramethrin on woolen cloth. The samples were extracted with acetonitrile and partitioned with benzene. Interferences were removed by liquid column chromatography with acid alumina and eluted with 10% ethyl acetate-hexane. Analysis was by gas chromatography with a 10% UCW98 (methylsilicone) column. Detection was made with the flame ionization detector to avoid the repeated dilutions necessary with use of the electron capture detector.This paper reflects the results of research only. Mention of a pesticide in this paper does not constitute a recommendation for use by the USDA nor does it imply registration under FIFRA as amended. Mention of a proprietary product does not constitute an endorsement by the USDA. |
| |
Keywords: | Gas chromatography Liquid chromatography Tetramethrin Residues |
本文献已被 SpringerLink 等数据库收录! |