Characteristics of large capacity ultrasonic complex vibration sources with stepped complex transverse vibration rods
Authors:Tsujino J  Ueoka T
Institution:Kanagawa University, Faculty of Engineering, 3-27-1 Rokkakubashi, Kanagawa-ku, Yokohama 221-8686, Japan. tsujino@cc.kanagawa-u.ac.jp
Abstract:Configurations of large capacity ultrasonic complex vibration sources with multiple longitudinal transducers are proposed and studied. The ultrasonic complex vibration systems are effective and essential for new applications in various industries. The complex vibration source of 27 kHz consists of a complex transverse rod with a welding tip (aluminum alloy, stainless steel and titanium alloy), a complex vibration rod with a flange and stepped part for holding the system, a circular longitudinal vibration disk (aluminum alloy) and six bolt-clamped Langevin type PLT transducers. Three transducer pairs are driven simultaneously using three driving systems at phase difference 120 degrees, and almost circular vibration locus is obtained.