首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Design and evaluation of highly sensitive luminescent terbium sensor for hypochlorite in water
Authors:Qianming Wang  Zhan Zhou
Institution:(1) School of Chemistry and Environment, South China Normal University, Guangzhou, 510006, People’s Republic of China;(2) State Key Laboratory of Coordination Chemistry, Nanjing University, Nanjing, 210093, People’s Republic of China
Abstract:A novel terbium 2-methyl-benzoimidazole-5-carboxylic acid complex was prepared and incorporated into silica matrix (tetraethoxysilane) using a mild sol–gel technique. We then successfully fabricated a terbium luminescent xerogel, which maintained intense green emission even in pure water. The emission was rapidly (~1 s) quenched by ClO (detection limit 10−5 M) but not NO3 , CH3COO, F, Cl, Br, I, CO3 , and OH. The selectivity appears to be due to the high vibrational energy of ClO as well as its strong oxidation capability.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏