首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Planar drop-sizing and liquid volume fraction measurements of airblast spray in cross-flow using SLIPI-based techniques
Institution:1. Spray and Combustion Laboratory, Discipline of Mechanical Engineering, Indian Institute of Technology Indore, Indore, 453552, India;2. Department of Mechanical Engineering, Government college of Engineering Amaravati, 444604, India
Abstract:This paper presents planar measurements of Sauter mean diameter (SMD) and liquid volume fraction distributions of airblast spray injected into cross-flow. The experiments are conducted using a combination of structured laser illumination planar imaging with laser sheet drop-sizing (SLIPI-LSD) and particle/droplet imaging analysis (PDIA) techniques. Effect of gas to liquid mass ratio (GLR) and cross-flow velocity (Ucross) is studied. Planar SMD distribution at low GLR improved with increase in Ucross due to secondary atomization of large droplets. Uniform SMD distribution in a range of 10–20 µm is observed for GLR more than 3. The distribution of liquid volume fraction at low GLR condition shows poor dispersion with most of the liquid concentrated near the injector. The liquid volume fraction distribution improves with increase in GLR and better dispersion is observed for GLR more than 3 and two-phase momentum ratio (q2) greater than 13.06. Spatial bifurcation in liquid fraction is found for high GLR conditions. The SMD in the range of 10–20  µm and uniform distribution of liquid are observed for GLR more than 3 and q2 > 25.6.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号