Development and Validation of a Sensitive and Specific LC-MS/MS Method for IWR-1-Endo,a Wnt Signaling Inhibitor: Application to a Cerebral Microdialysis Study |
| |
Authors: | Sreenath Nair Abigail Davis Olivia Campagne John D. Schuetz Clinton F. Stewart |
| |
Affiliation: | Department of Pharmacy and Pharmaceutical Science, St. Jude Children’s Research Hospital, Memphis, TN 38105, USA |
| |
Abstract: | IWR-1-endo, a small molecule that potently inhibits the Wnt/β-catenin signaling pathway by stabilizing the AXIN2 destruction complex, can inhibit drug efflux at the blood–brain barrier. To conduct murine cerebral microdialysis research, validated, sensitive, and reliable liquid chromatography–tandem mass spectrometry (LC-MS/MS) methods were used to determine IWR-1-endo concentration in the murine plasma and brain microdialysate. IWR-1-endo and the internal standard (ISTD) dabrafenib were extracted from murine plasma and microdialysate samples by a simple solid-phase extraction protocol performed on an Oasis HLB µElution plate. Chromatographic separation was executed on a Kinetex C18 (100A, 50 × 2.1 mm, 4 µm particle size) column with a binary gradient of water and acetonitrile, each having 0.1% formic acid, pumped at a flow rate of 0.6 mL/min. Detection by mass spectrometry was conducted in the positive selected reaction monitoring ion mode by monitoring mass transitions 410.40 > 344.10 (IWR-1-endo) and 520.40 > 307.20 (ISTD). The validated curve range of IWR-1-endo was 5–1000 ng/mL for the murine plasma method (r2 ≥ 0.99) and 0.5–500 ng/mL for the microdialysate method (r2 ≥ 0.99). The lower limit of quantification (LLOQ) was 5 ng/mL and 0.5 ng/mL for the murine plasma and microdialysate sample analysis method, respectively. Negligible matrix effects were observed in murine plasma and microdialysate samples. IWR-1-endo was extremely unstable in murine plasma. To improve the stability of IWR-1-endo, pH adjustments of 1.5 were introduced to murine plasma and microdialysate samples before sample storage and processing. With pH adjustment of 1.5 to the murine plasma and microdialysate samples, IWR-1-endo was stable across several tested conditions such as benchtop, autosampler, freeze–thaw, and long term at −80 °C. The LC-MS/MS methods were successfully applied to a murine pharmacokinetic and cerebral microdialysis study to characterize the unbound IWR-1-endo exposure in brain extracellular fluid and plasma. |
| |
Keywords: | IWR-1-endo Wnt signaling inhibitor LC-MS/MS solid-phase extraction pharmacokinetics cerebral microdialysis bioanalysis |
|
|