首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Hydrophilic interaction liquid chromatographic tandem mass spectrometric determination of atenolol in human plasma
Authors:Li Wenkui  Li Yinghe  Francisco Diane T  Naidong Weng
Institution:Covance Laboratories Inc., Madison, WI 53704, USA.
Abstract:A hydrophilic interaction liquid chromatographic method with tandem mass spectrometry for the determination of atenolol, a beta-blocking agent, in human plasma has been developed and validated over the curve range of 10--2000 ng/mL. The assay was based on protein precipitation followed by evaporation of the extraction solvent, reconstitution with acetonitrile, and chromatography on an Hypersil silica column (50 x 4.6 mm) using a low aqueous--high organic mobile phase. The mobile phase consists of 85% acetonitrile, 15% water, 0.5% acetic acid and 0.04% trifluoroacetic acid and runs isocratically at a flow rate of 2.0 mL/min. The column ef fluent was split so that 50% of it was transferred into the LC-MS/MS interface operated in positive electrospray ionization mode. The chromatographic run time was 2.0 min per injection. Atenolol and the internal standard, atenolol-d(7), showed a retention time of 1.0 min. The inter-day and intra-day precision and accuracy of the quality control samples were <5.3% relative standard deviation and <8.0% relative error, respectively. To explore the application of the current method for the analysis of other beta-blocking agents, propranolol and metoprolol were tested under the same chromatographic conditions with retention times of 0.68 and 0.75 min, respectively. The present method could be used for therapeutic drug monitoring, pharmacokinetic and drug--drug interaction studies of beta-blocking agents.
Keywords:atenolol  hydrophilic interaction liquid chromatography (HILIC)‐MS/MS  human plasma  propranolol  metoprolol
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号