Nickel/Copper Bilayer‐modified Screen Printed Electrode for Glucose Determination in Flow Injection Analysis
Abstract:This work reports about the performance of a Ni/Cu‐modified screen printed electrodes (SPE/Ni/Cu), prepared by physical vapor deposition (PVD) in an oblique angle configuration (OAD), for non‐enzymatic glucose sensing applications. SPE/Ni/Cu electrodes showed an excellent reversibility and a catalytic behavior for detection of glucose that were controlled by the diffusion of reactants up to the active sites at the electrode surface. The study with a flow injection analysis (FIA) setup of the main experimental variables affecting the detection process has shown that the developed electrode system had an excellent glucose sensitivity of 1.04 A M−1cm−2 (R2:0.999), a linear response up to 1 mM, a limit of detection of 0.33 μM and a time of analysis of ca. 30 s per sample. The selectivity of the sensor was checked against various interferences, including ascorbic acid, uric acid, acetaminophen and other sugars, in all cases with excellent results. The feasibility of using this sensor for practical applications was successfully confirmed by determining the glucose concentration in different commercial beverages.
Keywords:Glucose  screen printed electrode  flow injection analysis  physical vapor deposition  oblique angle deposition  GLAD