Abstract:This report investigates the electrochemical behavior of hexacyanoferrate casted on Ni‐Al2O3 modified electrodes and the preconcentration and detection of cesium ions on such films. It also studies the morphology and the composition of these surfaces. The film was grown on a glassy carbon (GC) surface. Five consecutive voltammetric cycles applied within 0.0 V and ?1.6 V at a scan rate of 10 mV/s were enough to cast the film. Scanning electron microscopy (SEM) analyses showed a homogeneous, porous but broken surface of the film. Its composition was studied by X‐ray diffraction (XRD). The presence of NiHCFe was confirmed by Fourier transformed infrared spectroscopy (FT‐IR). The Cs+ preconcentration from diluted solutions was accomplished in 90 s, under a negative potential of ?0.20 V applied to the modified working electrode. The detection of cesium has a good sensitivity and a wide linear interval (10?8 and 10?12 mol L?1). Even so, the limit of detection calculated was extremely low (2×10?16 mol L?1), cesium concentrations lower than 10?12 mol L?1 gave signals with no analytical significance. However, to our knowledge, this is the lowest level of cesium ever detected by an electroanalytical technique.
Keywords:Ni‐Al2O3 film  Preconcentration  Electrodeposits  Cesium  Hexacyanoferrate  Electroactivity  Thin films