Eddy current septum magnets for injection and extraction at SSRF |
| |
Authors: | OUYANG Lian-Hua GU Ming LIU Bo CHEN Rong |
| |
Affiliation: | Shanghai Synchrotron Radiction Facility, Shanghai 201203, China |
| |
Abstract: | There are 6 in-vacuum eddy current septum magnets used for booster injection, extraction, and storage ring injection in SSRF. Special attention was paid to coils and their support designs because of the shock force they bear in the magnetic fields and the high heat which is hard to be dissipated in vacuum environment. For the storage ring magnets, good transverse homogeneity in the gap was achieved by careful design, precise machining and accurate assembly; and an extremely low leakage field on the stored b... |
| |
Keywords: | injection and extraction eddy current septum magnets leakage field |
本文献已被 CNKI 维普 等数据库收录! |
| 点击此处可从《中国物理 C》浏览原始摘要信息 |
|