Comparison between the measured and calculated reactivity in measuring the effectiveness of the emergency protection at the stage of physical start-up of unit no. 3 at the Kalinin nuclear power plant |
| |
Authors: | O Yu Kavun A I Popykin R A Shevchenko S A Shevchenko |
| |
Institution: | 1. Scientific and Engineering Center for Nuclear and Radiation Safety, ul. Malaya Krasnosel??skaya 2/8, str. 5, Moscow, 107140, Russia
|
| |
Abstract: | This paper presents comparisons between the effectiveness of the emergency protection under both stationary and nonstationary formulations calculated with the use of the RADUGA-7.5 package 1] and experimental data obtained in measuring the ??weight?? of the emergency protection in the process of physical start-up of the VVER-1000 reactor of unit no. 3 of the Kalinin NPP. On the basis of the results obtained, recommendations are given on comparing the measured and calculated reactivity and parameters determined by using its value. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |