首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Verwendung von Cerenkovdetektoren zur Sauerstoffbestimmung mit Schnellen Reaktorneutronen
Authors:H B Lück  H Rommel
Institution:(1) Zentralinstitut für Kernforschung der Deutschen Akademie der Wissenschaften zu Berlin, Rossendorf bei Dresden, DDR
Abstract:Three variants of oxygen determination differing in their programs of activation and measuring are presented. The high energetic β-radiation of16N produced by16O(n, p)16N was detected by a Cerenkov-counter with scintillator of Piacryl (Lucite). Standard deviation and sensitivity of the three variants were investigated. Sensitivity in interference free samples amounts to 4 000 counts/mg of oxygen and the threshold of detection to 10 μg of oxygen. If the contents of oxygen is more than 1 mg, the standard deviation will be 1.25%.
Keywords:
本文献已被 SpringerLink 等数据库收录!