Abstract: | Abstract High performance liquid chromatographic (HPLC) and UV derivative spectrophotometric (UVDS) methods were developed and validated for the quantitative determination of sotalol hydrochloride in tablets. The HPLC method was performed on a C18 column with fluorescence detection. The excitation and emission wavelengths were 235 and 310 nm, respectively. The mobile phase was composed of acetonitrile-water containing 0.1% trietylamine (7:93 v/v) and pH adjusted to 4.6 with formic acid. The UVDS method was performed taking a signal at 239.1 nm in the first derivative. The correlation coefficients (r) obtained were 0.9998 and 0.9997 for HPLC and UVDS methods, respectively. The proposed methods are simple and adaptable to routine analysis. |