Determination of Low Level Sulfides in Environmental Waters by Automated Gas Dialysis/Methylene Blue Colorimetry
Abstract:Abstract

A sensitive and rapid automated method has been developed for the selective analysis of acid extractable sulfide in environmental samples by combining gas dialysis separation techniques with methylene blue detection procedures. Acid extractable sulfide is separated from the sample matrix by the gas dialysis membrane and subsequently trapped in a dilute sodium hydroxide receiving stream. This stream is reacted with N, N-dimethyl-p-phenylenediamine and ferric chloride to produce methylene blue which is then quantitated colorimetrically at 660 nm. For standards and nonturbid environmental samples, there is good agreement between the results obtained by this procedure and the standard methylene blue method. The effect of interferences on the accurate determination of sulfide by both methods was also examined and it was found that cupric ions significantly interfered with sulfide estimation. To obtain adequate sulfide recoveries in tap water and environmental samples ascorbic acid must be added as an antioxidant. A detection limit of 2 μg/L of sulfide has been obtained using this procedure.
Keywords:sulfide determination  gas dialysis/methylene blue colorimetry  automated  environmental analysis