首页 | 本学科首页   官方微博 | 高级检索  
     


Carbamide Peroxide Determination in Tooth Whitening Using a Reagentless HRP-Biosensor
Abstract:Abstract

A rapid and effective method for carbamide peroxide (CP) quantification in pharmaceuticals is proposed. The reagentless biosensor was prepared by using lyophilized turnip extract as horseradish peroxidase (HRP) enzyme source. The biosensor presented the best performance. The measurements were carried out in 0.1 mol L?1 Pipes buffer (pH 6.0). At ?100 mV vs. Ag|AgCl, a linear response range from 3.0 to 25.0 mmol L?1 was obtained. The quantification and detection limits were 1.2 and 0.4 mmol L?1, respectively, and the response time was 0.5 s. The biosensor repeatability, storage, and lifetime were excellent, allowing a satisfactory CP quantification in real pharmaceutical samples, when compared with those obtained by the official method.
Keywords:Amperometric biosensor  brassica napus L  carbamide peroxide  HRP  lyophilization procedure
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号