首页 | 本学科首页   官方微博 | 高级检索  
     


Electrode Hybride Pour la Determination de Phosphates et de Polyphosphates. Application aux Problemes Lies a l'Environnement
Abstract:Abstract

The determination of phosphates and polyphosphates has been effected using an hybrid electrode, which consists of a glucose oxydase enzymic membrane and a Solanum tuberosum tissue slice. This membrane, rich in acid phosphatase, catalyses the glucose-6-phosphate hydrolysis. This reaction is quantitatively inhibited by phosphate. Several factors involved in the electrode response, like substrate concentration, pH, ionic strength and type of buffer are discussed in detail. At a 4.10?4 M glucose-6-phosphate concentration, the linear ranges of phosphates and polyphosphates are, respectively, 6.10?5 M to 1.6.10?3 M and 3.10?5 M to 1.10?3 M. The urinary phosphate contents determinated by this biosensor are in good agrement with those obtained by usual spectrophotometric techniques.
Keywords:tissue and enzymatic biosensor  acid phosphatase of Solanum tuberosum and glucose oxydase  amperometry of H2O2