首页 | 本学科首页   官方微博 | 高级检索  
     检索      


GLC Determination of Chlorpheniramine in Human Plasma Using a Nitrogen Sensitive Thermionic Detector
Abstract:Abstract

A highly sensitive procedure for the determination of plasma levels of the antihistamine, chlorpheniramine (CPA) is presented. Following the administration of therapeutic doses (4–8 mg) of CPA, plasma levels of the drug can be expected to be low. To reliably and accurately measure such levels, an ultrasensitive means of determining the concentration is required. A preliminary extraction with ether, a back-wash into acid, a final basic extraction into hexane with subsequent measurement by a gas chromatograph equipped with a nitrogen sensitive detector, provides the required selectivity, sensitivity and speed of analysis. In an expenditure of less than 10 minutes, 1 ng of CPA per ml of plasma can be reliably determined.
Keywords:Chlorpheniramine  gas-liquid chromatography  Nitrogen detector  human plasma
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号