Abstract: | Abstract The preparation of a methacrylate polymer molecularly imprinted (MIP) with paracetamol (APAP) was performed. After extraction of the APAP template molecule, the MIPs were incorporated into a graphite–polyurethane (GPU) matrix, and the resulting composites were used to prepare modified electrodes intended to be used in APAP determination. The best results were found using a 2.5% MIP in the GPU electrode and a 500-µm MIP particle size. This electrode was used in the determination of APAP in pharmaceutical formulations, reaching a 6.7 × 10?8 mol L?1 limit of detection. The 2.5% MIP-GPU-modified electrode showed better sensitivity than the nonimprinted methacrylate GPU-modified electrodes. Interference of phenacetin in the APAP response decreased remarkably when the proposed electrode was used. |