首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Cloned plasmid DNA fragments as calibrators for controlling GMOs: different real-time duplex quantitative PCR methods
Authors:Email author" target="_blank">Isabel?TaverniersEmail author  Erik?Van?Bockstaele  Marc?De?Loose
Institution:(1) Department for Plant Genetics and Breeding (DVP-CLO), Ministry of the Flemish Community, Caritasstraat 21, 9090 Melle, Belgium;(2) Department of Plant Production, Ghent University, Coupure Links 653, 9000 Gent, Belgium
Abstract:Analytical real-time PCR technology is a powerful tool for implementation of the GMO labeling regulations enforced in the EU. The quality of analytical measurement data obtained by quantitative real-time PCR depends on the correct use of calibrator and reference materials (RMs). For GMO methods of analysis, the choice of appropriate RMs is currently under debate. So far, genomic DNA solutions from certified reference materials (CRMs) are most often used as calibrators for GMO quantification by means of real-time PCR. However, due to some intrinsic features of these CRMs, errors may be expected in the estimations of DNA sequence quantities. In this paper, two new real-time PCR methods are presented for Roundup Ready soybean, in which two types of plasmid DNA fragments are used as calibrators. Single-target plasmids (STPs) diluted in a background of genomic DNA were used in the first method. Multiple-target plasmids (MTPs) containing both sequences in one molecule were used as calibrators for the second method. Both methods simultaneously detect a promoter 35S sequence as GMO-specific target and a lectin gene sequence as endogenous reference target in a duplex PCR. For the estimation of relative GMO percentages both ldquodelta CTrdquo and ldquostandard curverdquo approaches are tested. Delta CT methods are based on direct comparison of measured CT values of both the GMO-specific target and the endogenous target. Standard curve methods measure absolute amounts of target copies or haploid genome equivalents. A duplex delta CT method with STP calibrators performed at least as well as a similar method with genomic DNA calibrators from commercial CRMs. Besides this, high quality results were obtained with a standard curve method using MTP calibrators. This paper demonstrates that plasmid DNA molecules containing either one or multiple target sequences form perfect alternative calibrators for GMO quantification and are especially suitable for duplex PCR reactions.Electronic Supplementary Material Supplementary material is available for this article if you access the article at . A link in the frame on the left on that page takes you directly to the supplementary material.
Keywords:Reference materials  Cloned plasmid DNA standard  Real-time PCR  Duplex quantification  GMO
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号