碘作氧化剂分光光度法测定水中的挥发酚
引用本文:王子宁,夏都灵,宋镇江.碘作氧化剂分光光度法测定水中的挥发酚[J].化学分析计量,2010,19(2):67-69.
作者姓名:王子宁  夏都灵  宋镇江
作者单位:电子科技大学,成都,610054
摘    要:研究了以碘作氧化剂、4-氨基安替比林(4-AAP)分光光度法测定水中的挥发酚,方法的检出限为1μg/L,线性范围为2~24 g/L,相关系数为0.9995。条件优化后,方法的精密度为3.5%,加标回收率为91.3%~118.0%,方法的精密度和准确度均符合要求。

关 键 词:挥发酚  4-氨基安替比林    提纯

DETERMINATION OF VOLATILE PHENOL IN WATER BY SPECTROPHOTOMETRY WITH IODINE AS OXIDIZER
Wang Zining,Xia Duling,Song Zhenjiang.DETERMINATION OF VOLATILE PHENOL IN WATER BY SPECTROPHOTOMETRY WITH IODINE AS OXIDIZER[J].Chemical Analysis And Meterage,2010,19(2):67-69.
Authors:Wang Zining  Xia Duling  Song Zhenjiang
Institution:( University of Electronic Science and Technology of China, Chengdu 610054, China)
Abstract:The experiment of detecting volatile phenol in water by 4-aminoantipyrine spectrophotometry and iodine as oxidizer showed that the limit of detection was 1 ug/L, and the linear range was 2.0 -24.0 ug/L, r =0.9995. After the experiment factors were optimized, the precision of the method was 3.5% , and the recoveries of standard addition was 96.3% - 106%. The precision and accuracy of experiment meet the requirement.
Keywords:volatile phenol  g-aminoantipyrine  iodine  purification