Continuous measurement of ozone in air by chemiluminescence using ndigo-5,5′-disulphonate
Authors:Koji Takeuchi  Shuzou Kutsuna  Takashi Ibusuki
Institution:Atmospheric Environment Protection Department, National Research Institute for Pollution and Resources, Agency of Industrial Science and Technology, 16-3 Onogawa, Tsukuba, Ibaraki 305 Japan
Abstract:Gas-phase ozone was continuously measured by using the chemiluminescent reaction between indigo-5,5′-disulphonate and ozone. A detection limit of 0.4 ppb (v/v) was obtained using a reaction cell of 0.7 ml at a sampling rate of 15.0 ml min?1. The method was applied to the monitoring of ozone in the atmosphere.