Determination of polydextrose in foods by ion chromatography: collaborative study
Authors:Craig S A  Holden J F  Khaled M Y
Institution:Danisco Cultor, Ardsley, NY 10502, USA.
Abstract:Eight collaborating laboratories assayed 7 blind duplicate pairs of foods for polydextrose content. The 7 test sample pairs ranged from low (2%) to high (95%) levels. The following foods were prepared with polydextrose mixed into the other ingredients and then baked, cooked, or otherwise prepared: milk chocolate candy, iced tea, sugar cookie, grape jelly, soft jellied candy, and powdered drink mix. Collaborators received a polydextrose standard to develop a calibration curve. The method determined polydextrose by ion chromatography, after removal of interfering food components (high molecular weight solubles). Repeatability standard deviations (RSDr) ranged from 3.93 to 9.04%; reproducibility standard deviations (RSDR) ranged from 4.48 to 14.06%. The average recovery was 94%.