首页 | 本学科首页   官方微博 | 高级检索  
     


PIV with volume lighting in a narrow cell: An efficient method to measure large velocity fields of rapidly varying flows
Authors:Matthieu RoudetAnne-Marie Billet,Fré    ric RissoVé  ronique Roig
Affiliation:a LGC, Université de Toulouse (INPT, UPS) and CNRS. 4 Allée Emile Monso, BP74233, Toulouse Cedex 4, 31432, France
b IMFT, Université de Toulouse (INPT, UPS) and CNRS. Allée Camille Soula, Toulouse 31400, France
Abstract:In this work we test a methodology for PIV measurements when a large field of view is required in planar confined geometries. Using a depth of field larger than the channel width, we intend to measure the in-plane variations of the velocity of the fluid averaged through the width of the channel, and we examine in which operating conditions this becomes possible. Measurements of the flow through a narrow channel by PIV are challenging because of the strong velocity gradients that develop between the walls. In particular, all techniques that use small particles as tracers have to deal with the possible migration of the tracers in the direction perpendicular to the walls. Among the complex mechanisms for migration, we focus on the so called Segré-Silberberg effect which can lead to transverse migration of neutrally buoyant tracers of finite size. We report experimental PIV measurements in a Hele-Shaw cell of 1 mm gap, which have been carried out by using neutrally buoyant tracers of size around 10 μm. By considering steady flows, we have observed, in particular flow regimes, the effect of an accumulation of the tracers at a certain distance to the wall due to the so called Segré-Silberberg effect. The particle migration is expected to occur at any Reynolds numbers but the migration velocity depends on the Reynolds number. A significant migration therefore takes place each time the observation duration is large enough compared to the migration time. For a given observation duration, the tracers remain uniformly distributed at low Reynolds numbers whereas they all accumulate at the equilibrium position at large ones. When using volume lighting, the PIV algorithm provides the average velocity of the flow through the gap at low Reynolds number, while it leads to the velocity of the flow at the equilibrium position of the tracers at large Reynolds numbers. By considering unsteady flows, we have observed that the migration does not occur if the timescale of flow variation is short compared to the time required for the parabolic flow to develop across the gap. In this case, there is no transverse velocity gradient and the PIV algorithm provides the fluid velocity. Altogether, these results allow us to propose guidelines for the interpretation of PIV measurements in confined flow, which are based on the theoretical predictions of the tracer migration derived by Asmolov [1].
Keywords:Experimental methodology   PIV measurement   Volume illumination   Segré  -Silberberg effect   Tracer migration
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号