首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Flame four-dimensional deflection tomography with compressed-sensing-revision reconstruction
Institution:College of Electromechanical Engineering, Qingdao University of Science and Technology, Qingdao 266061, China
Abstract:Deflection tomography with limited angle projections was investigated to visualize a premixed flame. A projection sampling system for deflection tomography was used to obtain chronological deflectogram arrays at six view angles with only a pair of gratings. A new iterative reconstruction algorithm with deflection angle compressed-sensing revision was developed to improve reconstruction-distribution quality from incomplete projection data. Numerical simulation and error analysis provided a good indication of algorithm precision and convergence. In the experiment, 150 fringes were processed, and temperature distributions in 20 cross-sections were reconstructed from projection data in four instants. Four-dimensional flame structures and temperature distributions in the flame interior were visualized using the visualization toolkit. The experimental reconstruction was then compared with the result obtained from computational fluid dynamic analysis.
Keywords:Deflection tomography  Four-dimensional visualization  Premixed combustion  Array projection sampling  Reconstruction algorithm
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号