Thermal analysis of the CSNS H~- ion source |
| |
Authors: | WU Xiao-Bing OUYANG Hua-Fu Institute of High Energy Physics CAS Beijing China Graduate University of CAS China |
| |
Affiliation: | WU Xiao-Bing1,2 OUYANG Hua-Fu1 1 Institute of High Energy Physics,CAS,Beijing 100049,China 2 Graduate University of CAS,China |
| |
Abstract: | There are two cooling systems to maintain the thermal stability of the CSNS H- ion source during its operation:Air-cooling in the source body of the discharging chamber and water-cooling in the flange on which the discharging chamber is installed.The optimal cooling parameters to ensure the operation of the H- ion source are determined through a thermal analysis.In addition,a transient analysis is also performed to know exactly the transient temperature variation during the whole 40 ms period of the pulsed ... |
| |
Keywords: | H- ion source water-cooling air-cooling |
本文献已被 CNKI 等数据库收录! |