首页 | 本学科首页   官方微博 | 高级检索  
     


Conditions for sample preparation and quantitative HPLC/MS-MS analysis of bulky adducts to serum albumin with diolepoxides of polycyclic aromatic hydrocarbons as models
Authors:Emelie Westberg  Ulla Hedebrant  Johanna Haglund  Tomas Alsberg  Johan Eriksson  Albrecht Seidel  Margareta Törnqvist
Affiliation:1. Division of Environmental Chemistry, Department of Materials and Environmental Chemistry, Stockholm University, Svante Arrhenius v?g 16c, 10691, Stockholm, Sweden
4. MetaSafe AB, Biovation Park Telge, 15136, S?dert?lje, Sweden
2. Department of Applied Environmental Science, Stockholm University, Svante Arrhenius v?g 8, 11418, Stockholm, Sweden
3. Biochemical Institute for Environmental Carcinogens, Prof. Dr. Gernot Grimmer-Foundation, Lurup 4, 22927, Grosshansdorf, Germany
Abstract:Stable adducts to serum albumin (SA) from electrophilic and genotoxic compounds/metabolites can be used as biomarkers for quantification of the corresponding in vivo dose. In the present study, conditions for specific analysis of stable adducts to SA formed from carcinogenic polycyclic aromatic hydrocarbons (PAH) were evaluated in order to achieve a sensitive and reproducible quantitative method. Bulky adducts from diolepoxides (DE) of PAH, primarily DE of benzo[a]pyrene (BPDE) and also DE of dibenzo[a,l]pyrene (DBPDE) and dibenzo[a,h]anthracene (DBADE), were used as model compounds. The alkylated peptides obtained after enzymatic hydrolysis of human SA modified with the different PAHDE were principally PAHDE-His-Pro, PAHDE-His-Pro-Tyr and PAHDE-Lys. Alkaline hydrolysis under optimised conditions gave the BPDE-His as the single analyte of alkylated His, but also indicated degradation of this adduct. It was not possible to obtain the BPDE-His as one analyte from BPDE-alkylated SA through modifications of the enzymatic hydrolysis. The BPDE-His adduct was shown to be stable during the weak acidic conditions used in the isolation of SA. Enrichment by HPLC or SPE, but not butanol extraction, gave good recovery, using Protein LoBind tubes. A simple internal standard (IS) approach using SA modified with other PAHDE as IS was shown to be applicable. A robust analytical procedure based on digestion with pronase, enrichment by HPLC or SPE, and analysis with HPLC/MS-MS electrospray ionisation was achieved. A good reproducibility (coefficient of variation (CV) 11 %) was obtained, and the achieved limit of detection for the studied PAHDE, using standard instrumentation, was approximately 1 fmol adduct/mg SA analysing extract from 5 mg SA.
Figure
An outline of the method for analysis of bulky SA-adducts. All steps/conditions were evaluated.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏