Development of two fully automated quick,easy, cheap,effective, rugged,and safe pretreatment methods for the extraction of psychotropic drugs from whole blood samples
Authors:Takaya Murakami  Reiko Ishimaru  Eriko Minami  Yoshiaki Iwamuro  Naoki Takamura  Aya Torai  Tsutomu Watanabe  Akihiro Miki  Munehiro Katagi  Maiko Kusano  Hitoshi Tsuchihashi  Kei Zaitsu  Satoshi Chinaka
Institution:1. Forensic Science Laboratory, Ishikawa Prefectural Police Headquarters, Kanazawa, Japan;2. Shimadzu Trustech Corporation, Kyoto, Japan;3. Forensic Science Laboratory, Osaka Prefectural Police Headquarters, Osaka, Japan;4. Department of Legal Medicine, Osaka Medical and Pharmaceutical University, Osaka, Japan;5. Department of Legal Medicine, Showa University School of Medicine, Tokyo, Japan;6. Shimadzu Corporation, Kyoto, Japan;7. Multimodal Informatics and Wide-data Analytics Laboratory, Department of Computational Systems Biology, Faculty of Biology-Oriented Science and Technology, Kindai University, Wakayama, Japan;8. Forensic Science Laboratory, Ishikawa Prefectural Police Headquarters, Kanazawa, Japan

Department of Forensic Medicine and Pathology, Kanazawa University Graduate School of Medical Sciences, Kanazawa, Japan

Abstract:Quick, easy, cheap, effective, rugged, and safe extraction strategies are becoming increasingly adopted in various analytical fields to determine drugs in biological specimens. In the present study, we developed two fully automated quick, easy, cheap, effective, rugged, and safe extraction methods based on acetonitrile salting-out assisted liquid-liquid extraction (method 1) and acetonitrile salting-out assisted liquid-liquid extraction followed by dispersive solid-phase extraction (method 2) using a commercially available automated liquid-liquid extraction system. We applied these methods to the extraction of 14 psychotropic drugs (11 benzodiazepines and carbamazepine, quetiapine, and zolpidem) from whole blood samples. Both methods prior to liquid chromatography–tandem mass spectrometry analysis exhibited high linearity of calibration curves (correlation coefficients, > 0.9997), ppt level detection sensitivities, and satisfactory precisions (< 8.6% relative standard deviation), accuracies (within ± 16% relative error), and matrix effects (81–111%). Method 1 provided higher recovery rates (80–91%) than method 2 (72–86%), whereas method 2 provided higher detection sensitivities (limits of detection, 0.003–0.094 ng/mL) than method 1 (0.025–0.47 ng/mL) owing to the effectiveness of its dispersive solid-phase extraction cleanup step. These fully automated extraction methods realize reliable, labor-saving, user-friendly, and hygienic extraction of target analytes from whole blood samples.
Keywords:fully automated pretreatment  liquid chromatography–tandem mass spectrometry  psychotropic drug  quick  easy  cheap  effective  rugged  and safe extraction  whole blood