首页 | 本学科首页   官方微博 | 高级检索  
     

Graphene Oxide Doped Poly(hydroxymethylated-3,4- ethylenedioxythiophene): Enhanced Sensitivity for Electrochemical Determination of Rutin and Ascorbic Acid
引用本文:卢丽敏,徐景坤. Graphene Oxide Doped Poly(hydroxymethylated-3,4- ethylenedioxythiophene): Enhanced Sensitivity for Electrochemical Determination of Rutin and Ascorbic Acid[J]. 高分子科学, 2014, 32(8): 1019-1031. DOI: 10.1007/s10118-014-1484-z
作者姓名:卢丽敏  徐景坤
作者单位:[1]College of Science, Jiangxi Agricultural University, Nanchang 330045, China; [2]Jiangxi Key Laboratory of Organic Chemistry, Jiangxi Science and Technology Normal University, Nanchang 330013, China
基金项目:financially supported by the National Natural Science Foundation of China(Nos.50963002,51073074,51272906,51263010 and 51302117);Natural Science Foundation of Jiangxi Province(Nos.2010GZH0041,20122BAB213007);Jiangxi Provincial Department of Education(Nos.GJJ11590,GJJ10678 and GJJ13258);Jiangxi Science&;Technology Normal University Innovation Fund of Postgraduates(YC2013-X25)
摘    要:A novel graphene oxide doped poly(hydroxymethylated-3,4-ethylenedioxythiophene)(PEDOT-MeOH/GO) composite film was synthesized and utilized as an efficient electrode material for simultaneous detection of rutin and ascorbic acid(AA). PEDOT-MeOH/GO films were synthesized on glassy carbon electrode(GCE) by a facile one-step electrochemical approach and were characterized by scanning electron microscopy, UV-Vis spectroscopy, FTIR spectra and electrochemical methods. Then the PEDOT-MeOH/GO/GCE was applied successfully in the simultaneous detection of rutin and AA. The results showed that the oxidation peak currents of rutin and AA obtained at the PEDOT-MeOH/GO/GCE were much higher than those at the traditional conducting polymer PEDOT/GO/GCE, PEDOT-MeOH/GCE, PEDOT/GCE and bare GCE. Under optimized conditions, the linear ranges for rutin and AA are 20 nmol/L-10 μmol/L and 8 μmol/L-1 mmol/L, respectively. The detection limit is 6 nmol/L for rutin and 2 μmol/L for AA(S/N = 3), which are lower than those of the reported electrochemical sensors.

关 键 词:氧化物掺杂  氧化石墨  羟甲基化  抗坏血酸  电化学测定  芦丁  灵敏度  扫描电子显微镜

Graphene oxide doped poly(hydroxymethylated-3,4-ethylenedioxythiophene): enhanced sensitivity for electrochemical determination of rutin and ascorbic acid
Li-ping Wu,Long Zhang,Li-min Lu,Xue-min Duan,Jing-kun Xu,Tao Nie. Graphene oxide doped poly(hydroxymethylated-3,4-ethylenedioxythiophene): enhanced sensitivity for electrochemical determination of rutin and ascorbic acid[J]. Chinese Journal of Polymer Science, 2014, 32(8): 1019-1031. DOI: 10.1007/s10118-014-1484-z
Authors:Li-ping Wu  Long Zhang  Li-min Lu  Xue-min Duan  Jing-kun Xu  Tao Nie
Affiliation:1. College of Science, Jiangxi Agricultural University, Nanchang, 330045, China
2. Jiangxi Key Laboratory of Organic Chemistry, Jiangxi Science and Technology Normal University, Nanchang, 330013, China
Abstract:Conducting polymer Graphene oxide Nanocomposites Simultaneous determination Electrochemical sensor.
Keywords:Conducting polymer  Graphene oxide  Nanocomposites  Simultaneous determination  Electrochemical sensor.
本文献已被 CNKI 维普 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号