首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Merit of estimations from DSC measurements for the efficiency of optical resolutions
Authors:J Madarász  D Kozma  G Pokol  M Ács  E Fogassy
Institution:(1) Institute for General and Analytical Chemistry, Technical University of Budapest, Gellért tér 4, H-1521 Budapest, Hungary;(2) Department of Organic Chemical Technology, Technical University of Budapest, Müegyetem rkp. 3, H-1521 Budapest, Hungary
Abstract:Chiral drugs are generally resolved through formation of diastereoisomeric salts of different solubility. When the diastereoisomer salts from a eutectic in the solid phase, a good estimate can be made for the efficiency of the resolution (S), through a calculation based on the eutectic composition (x eu). The eutectic composition can be computed from thermal data of a differential scanning calorimetric (DSC) measurement of the diastereoisomeric salts 1]. In this work we investigated the influence of uncertainties of thermal data on the estimation of the efficiency of resolution (S), spreading throughout the calculations involved. Performance of our error-estimating method is demonstrated on 6 diastereoisomer salt pairs. The obtained deviations are close to the deviations of resolution experiments. Thus, it can be concluded that the DSC measurements are useful means in predicting the efficiency of resolutions. Deceased
Keywords:DSC  efficiency of optical resolution  error estimation  eutectic phase diagram
本文献已被 SpringerLink 等数据库收录!