首页 | 本学科首页   官方微博 | 高级检索  
     

Electroosmotic Driving Liquid Using Nanosilica Packed Column
引用本文:Ling Xin CHEN,Guo An LUO,Tao WEN Department of Chemistry,Tsinghua University,Beijing 100084. Electroosmotic Driving Liquid Using Nanosilica Packed Column[J]. 中国化学快报, 2005, 16(6)
作者姓名:Ling Xin CHEN  Guo An LUO  Tao WEN Department of Chemistry  Tsinghua University  Beijing 100084
作者单位:Ling Xin CHEN,Guo An LUO,Tao WEN Department of Chemistry,Tsinghua University,Beijing 100084
摘    要:The packed-bed electroosmotic pump (p-EOP) can manipulate liquid with pressure as high as 50 MPa and micro flowrate ranging from several nL/ min to several μL/min1-3. The p-EOP is matching to micro systems and suitable for developing chip liquid chromatography/electrochromatography for proteomics and high throughput HPLC for drug discovery4-6. There are some efforts to improve the performance p-EOP7-8 recently. In this paper, the nanosilica was chosen as the electroosmotic carrier to i…


Electroosmotic Driving Liquid Using Nanosilica Packed Column
Ling Xin CHEN,Guo An LUO,Tao WEN. Electroosmotic Driving Liquid Using Nanosilica Packed Column[J]. Chinese Chemical Letters, 2005, 16(6)
Authors:Ling Xin CHEN  Guo An LUO  Tao WEN
Affiliation:Ling Xin CHEN,Guo An LUO,Tao WEN Department of Chemistry,Tsinghua University,Beijing 100084
Abstract:The electroosmotic pump (EOP) using nanosilica particles packed-bed column was experimentally studied. The relationship between flowrate, pressure and applied voltage of the pump, and pressure-flowrate (P-Q) characteristic were investigated.
Keywords:Electroosmotic pump   nanosilica   nanochannel   chip.
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号