首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of fenthion and oxidation products in personal protection equipment by gas chromatography
Authors:Tsakirakis Angelos  Machera Kyriaki
Institution:Laboratory of Pesticides Toxicology, Benaki Phytopathological Institute, 8 St. Delta Street, Kifissia 14561, Athens, Greece.
Abstract:A method for the co-extraction and simultaneous chromatographic determination of fenthion and its five oxidation products (or metabolites) fenoxon, fenoxon-sulfoxide, fenoxon-sulfone, fenthion-sulfoxide, and fenthion-sulfone in personal protection equipment (PPE) of pesticide applicators was developed and validated. Capillary gas chromatography-nitrogen-phosphorus detection was used for the analytical determination of all the aforementioned compounds over the concentration range of 0.1-0.5 microg/mL. All necessary validation criteria of the method were met. The method was found to be highly selective, accurate, and precise, gave satisfactory recovery (>70%) and RSD values (<20%) for fenthion and its metabolites in all tested specimens of personal protection equipment and in air samplers. The limit of quantification (LOQ) and linearity were determined for the most relevant PPE (i.e. inner coverall) for the parent compound and for the metabolites. The LOQ values ranged from 0.05 to 0.1 ppb while the linearity in the tested range of 0.1-0.5 ppm had r(2)>0.994 for all analytes.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏