首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Development of an Electrochemical Biosensor for the Rapid Detection of Carbofuran Based on Air Stable Lipid Films with Incorporated Calix[4]arene Phosphoryl Receptor
Authors:Dimitrios P Nikolelis  Garyfallia Raftopoulou  Nikos Psaroudakis  Georgia‐Paraskevi Nikoleli
Institution:1. Laboratory of Environmental Chemistry, Department of Chemistry, University of Athens, Panepistimiopolis‐Kouponia, 15771‐Athens, Greece;2. Laboratory of Inorganic Chemistry, Department of Chemistry, University of Athens, Panepistimiopolis‐Kouponia, 15771‐Athens, Greece
Abstract:This work describes the preparation of a selective receptor for the rapid, selective and sensitive electrochemical flow injection analysis of carbofuran in foods using air stable lipid films supported on a methacrylate polymer on a glass fiber filter with incorporated artificial receptor. The selective receptor was synthesized by transformation of the ? OH groups of resorcin4]arene receptor into phosphoryl groups. These lipid films were supported on a methylacrylate polymer (i.e., methacrylic acid was the functional monomer for the polymerization, ethylene glycol dimethacrylate was used as the crosslinker and 2,2′‐azobis‐2‐methylpropionitrile as an initiator). A minisensor device was constructed for the electrochemical flow injection analysis of toxicants based on air stabilized lipid films supported on a polymer. The device can sense the analyte in a drop (50 μL) of sample. Carbofuran was injected into flowing streams of a carrier electrolyte solution. A host‐guest complex formation between the calix4]arene phosphoryl receptor and carbofuran takes place through hydrogen bonding. This enhances the preconcentration of carbofuran at the lipid membrane surface which in turn causes dynamic alterations of the electrostatic fields and phase structure of membranes; as a result ion current transients were obtained and the magnitude of these signals was correlated to the substrate concentration. The response times were ca. 80 s and carbofuran was determined at concentration levels of nM. The effect of potent interferences included a wide range of compounds and other insecticides. The effect of interference of proteins and lipids was also examined. The reproducibility of the method was checked by recovery experiments in fruit and vegetable samples with satisfactory results.
Keywords:Electrochemical biosensors  Lipid films  Artificial receptor  Calix[4]arene phosphoryl receptor  Carbofuran
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号