首页 | 本学科首页   官方微博 | 高级检索  
     

两个不可逆电对共存体系的流动注射双安培分析法
引用本文:宋俊峰,赵川,亢晓峰,过玮. 两个不可逆电对共存体系的流动注射双安培分析法[J]. 高等学校化学学报, 2000, 21(4): 535-537
作者姓名:宋俊峰  赵川  亢晓峰  过玮
作者单位:西北大学电分析化学研究所, 西安 710069
基金项目:国家自然科学基金! (批准号 :2 9875 0 17)
摘    要:流动注射分析已有电位法[1]、单安培法[2]和双安培法[3~8]等电化学检测方法.安培法比电位法灵敏,颇受重视.单安培法由于在控制工作电位范围内受其它可氧化还原物质的干扰,选择性不高.双安培法仪器装置较简单,但应用范围仅限于I2/I-,Fe3+/Fe2+等少数几种可逆电对体系.迄今为止,尚未见到将双安培法应用于不可逆体系的报道.本文讨论两个独立的不可逆电对共存的流动注射双安培检测法,以拓展双安培法的应用范围,并选用溶解氧分别与抗坏血酸、羟胺和联氨构成的3个体系进行了考察验证.1 实验部分1.1 仪器和试剂 流动注射双安培检测系统由IFI…

关 键 词:双安培法  流动注射分析  不可逆电对  
收稿时间:1999-12-16

Flow Injection Biamperometry for Irreversible Couple Systems
SONG Jun-Feng,ZHAO Chuan,KANG Xiao-Feng,GUO Wei. Flow Injection Biamperometry for Irreversible Couple Systems[J]. Chemical Research In Chinese Universities, 2000, 21(4): 535-537
Authors:SONG Jun-Feng  ZHAO Chuan  KANG Xiao-Feng  GUO Wei
Affiliation:Institute of Electroanalytical Chemistry, Northwest University, Xi'an 710069, China
Abstract:Flow injection biamperometry was extended to irreversible couple systems. For the biamperometry, the essential condition is the coexistence of two reactants, with opposite electrode reaction, of two independent and irreversible couples in the same system. The system can be skillfully constructed with analyte by choosing such a reactant of one couple as its standard redox potential which was better closed to that of the analyte as nearly as possible. In the chosen system, provided the real potentials of the two working electrodes have exceeded the deposition potential of two reactants by imposing a suitable potential difference ΔEbetween these two electrodes, faradic current i will flow through circuit. When the concentration of the chosen reactant remains larger constant, the circuit current i will be linearly proportional to the analyte of interest over certain concentration range. To verify the feasibility of the biamperometry, three systems of the dissolved oxygen separately with ascorbic acid, hydrazine chloride and hydroxyamine chloride were examed. In phosphate buffer(pH 6.9 ) solution containing the dissolved oxygen, using two activated platinum wire working electrodes imposed by potential difference Δ E0.0 V, the circuit current i was linearly proportional to these three analytes in the concentration range of 1×10-5 -1×10-3 mol/Lfor ascorbic acid, 1×10-6 -1×10-4 mol/Lfor hydrazine chloride and hydroxyamine chloride, respectively.
Keywords:Biamperometry  Flow injection analysis  Irreversible couple  
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《高等学校化学学报》浏览原始摘要信息
点击此处可从《高等学校化学学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号