首页 | 本学科首页   官方微博 | 高级检索  
     


Potentiometric stripping analysis for mercury after preconcentration in a potassium permanganate trap
Authors:Daniel Jagner  Kerstin Årén
Affiliation:Department of Analytical and Marine Chemistry, University of Göteborg and Chalmers University of Technology, S-412 96 GöteborgSweden
Abstract:Water samples of total volume 0.5–5 l, containing mercury in the range 0.05–5 μg l-1 are oxidized with excess of potassium permanganate and then reduced with tin(II) chloride. The mercury is transferred to 5–10 ml of a dilute potassium permanganate trap solution by cycling air through the sample and the trap solution. The mercury(II) content of the trap solution is determined by potentiometric stripping analysis. The accuracy, precision and detection limit of the technique are discussed.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号