首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Spectrophotometric determination of iron as phenylfluorone complex sensitized with Triton X-100
Authors:M Tarek  M Zaki and A Y El-Sayed
Institution:(1) Department of Chemistry, Faculty of Science, Ain Shams University, Abassia, Cairo, Egypt
Abstract:Summary The effect of some surfactants and protective colloids on the absorbance of the iron(III)-phenylfluorone complex has been investigated. The binary complex formed at pH 9.0 show a molar absorptivity of 7.5×104 l · mol–1 · cm–1 at 530 nm. In the presence of 2% Triton X-100, at the same pH, the molar absorptivity of the sensitized complex was 1.19×105 l · mo–1 · cm–1 at 555 nm. Full colour development of the sensitized complex occurred within 25 min and Beer's law was followed up to 0.53 ppm of iron. The molar ratio and continuous variation methods indicated a 1ratio3 metal-ligand ratio for the sensitized complex. The effect of various amounts of different ions has been studied under the experimental conditions and some masking agents were recommended. The method has been applied to the determination of iron in copper and nickel metals and some non-ferrous alloys.
Spektralphotometrische Bestimmung von Eisen als Phenylfluoronkomplex sensibilisiert mit Triton X-100
Keywords:
本文献已被 SpringerLink 等数据库收录!