A Movable-Cavity Cold Atom Space Clock |
| |
作者姓名: | 边风刚 魏荣 姜海峰 王育竹 |
| |
作者单位: | [1]KeyLaboratoryofQuantumOptics,ShanghaiInstituteofOpticsandFineMechanics,ChineseAcademyofSciences,Shanghai201800 [2]KeyLaboratoryofQuantumOptics,ShanghaiInstituteofOpticsandFineMechanics,ChineseAcademyofSciences,Shanghai201800//GraduateSchooloftheChineseAcademyofSciences,Beijing100039 |
| |
摘 要: | We present an experimental scheme of a cold atom space clock with a movable cavity. By using a single microwave cavity, we find that the clock has a significant advantage, i.e. the longitudinal cavity phase shift is eliminated. A theoretical analysis has been carried out in terms of the relation between the atomic transition probability and the velocity of the moving cavity by taking into account the velocity distribution of cold atoms. The requirements for the microwave power and its stability for atomic π/2 excitation at different moving velocities of the cavity lead to the determination of the proper working parameters of the rubidium clock in frequency accuracy 10^-17. Finally, the mechanical stability for the scheme is analysed and the ways of solving the possible mechanical instability of the device are proposed.
|
关 键 词: | 运动微波腔 冷却方法 原子钟 相位移 |
本文献已被 维普 等数据库收录! |
|