首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Simulation of conditions for the maximal efficiency of decimeter-wave klystrons
Authors:A Yu Baikov  O A Grushina  M N Strikhanov
Institution:1. Moscow University of Finance and Law, Bol’shaya Cheremushkinskaya ul. 17-A, Moscow, 117447, Russia
2. National Research Nuclear University (MEPhI), Kashirskoe sh. 31, Moscow, 115409, Russia
Abstract:Using the mathematical model of electron beam transformation in a narrow tube developed by the authors and the KlypWin program suite, conditions for the maximal efficiency of decimeter-wave klystrons having from three to six amplification stages are simulated. Simulation is based on a real electron-optical system and real parameters of the cavities. It is shown that the maximal efficiency (across the load) is 83% for a four-cavity klystron, 86% for a five-cavity klystron, 88% for a six-cavity klystron, and 90% for a seven-cavity one. The electronic efficiency of the simulated seven-cavity klystron equals 94%, which implies the achievement of a global extremum.
Keywords:
本文献已被 SpringerLink 等数据库收录!