首页 | 本学科首页   官方微博 | 高级检索  
     


An experimental study of relative humidity and air flow effects on positive and negative corona discharges in a corona-needle charger
Affiliation:1. Department of Mechanical Engineering, Faculty of Engineering, Chiang Mai University, Chiang Mai 50200, Thailand;2. Research Unit of Electrostatic Applications in Energy and Environment (RUEE), College of Integrated Science and Technology, Rajamangala University of Technology Lanna, Chiang Mai 50220, Thailand;3. Center of Excellence in Electromagnetic Energy Utilization in Engineering (CEEE), Department of Mechanical Engineering, Faculty of Engineering, Thammasat University, Pathum Thani 12121, Thailand;1. School of Materials and Energy, Guangdong University of Technology, Guangzhou, Guangdong 510006, PR China;2. Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Kowloon, Hong Kong, China;1. Centre for Plasma and Laser Engineering, The Szewalski Institute of Fluid Flow Machinery, Polish Academy of Sciences, Fiszera 14, 80-231 Gdansk, Poland;2. Department of Marine Electronics, Gdynia Maritime University, Morska 81-87, 81-225 Gdynia, Poland
Abstract:In this paper, the effects of inlet air RH and air flow rate on positive and negative corona discharges in a corona-needle charger have been experimentally studied and discussed. Its corona discharge characterizations in terms of current-to-voltage relationships of the corona-needle charger on the effects of inlet air RH and air flow rate were evaluated at applied corona voltages between 0 and 3.1 kV, an air flow rates between 5 and 15 L/min, a relative humidity between 20 and 90%, and an operating pressure of about 101.3 kPa. Experimental results were shown that discharge current is strongly affected by the RH level of the inlet air. The positive discharge current was found to be decreased with increasing RH value at RH values below 60% and increased with increasing RH value at RH value above 60% in the same corona voltage. The negative discharge current was found to be stable with increasing RH value at RH values below 40% and increased with increasing RH value at RH value above 40% in the same corona voltage. For the air flow rate effects, the positive discharge current was found to slightly decrease when the air flow rate increased at RH value below 90% and to increase with the air flow rate at RH value of 90%. For the negative corona, the discharge current was also found to monotonically decrease when the air flow rate increased.
Keywords:Relative humidity  Corona discharge  Particle charging  Aerosol charger
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号