Identification,characterization, and high‐performance liquid chromatography quantification of process‐related impurities in vonoprazan fumarate |
| |
Authors: | Lei Liu Na Cao Xingling Ma Kaihe Xiong Lili Sun Qiaogen Zou |
| |
Abstract: | High‐performance liquid chromatography analysis of vonoprazan fumarate, a novel proton pump inhibitor drug revealed six impurities. These were identified by liquid chromatography with mass spectrometry. Further, the structures of the impurities were confirmed by synthesis followed by characterization by mass spectrometry, NMR spectroscopy, and infrared spectroscopy. On the basis of these data and knowledge of the synthetic scheme of vonoprazan fumarate, the previously unknown impurity was identified as 1‐[5‐(2‐fluorophenyl)‐1‐(pyridin‐3‐ylsulfonyl)‐1H‐pyrrol‐3‐yl]‐N‐methyldimethylamine, which is a new compound. The possible mechanisms by which these impurities were formed were also discussed. A high‐performance liquid chromatography method was optimized in order to separate, selectively detect, and quantify all process‐related impurities of vonoprazan fumarate. The presented method has been validated in terms of linearity, limits of detection, and quantification, and response factors and, therefore, is highly suitable for routine analysis of vonoprazan fumarate related substances as well as stability studies. |
| |
Keywords: | High‐performance liquid chromatography Process‐related impurities Vonoprazan fumarate |
|
|